Difference between revisions of "Microscopes"

From Wiki
Jump to navigation Jump to search
(Created page with " == Raffi's Spinning Disk Confocal Microscope == {| |Microscope |Nikon TE2000 |- |Light Sources |Xeon Arc Lamp, Halogen Lamp, 4 Lasers (405nm, 488nm, 561nm, 636nm) |- |Wide...")
 
Line 10: Line 10:
 
|-
 
|-
 
|Wide Field Camera
 
|Wide Field Camera
|Photometrics CoolSNAP HQ, 1392x1040, 12 bits, 6.45um2 pixels, QE: 55-62%  
+
|Photometrics CoolSNAP HQ, 1392x1040, 12 bits, 6.45um<sup>2</sup> pixels, QE: 55-62%  
 
|-
 
|-
 
|Spinning Disk Camera
 
|Spinning Disk Camera
Line 53: Line 53:
 
|-
 
|-
 
|Spinning Disk Camera
 
|Spinning Disk Camera
| Hamamatsu C4742-80, 1344x1024, 12 bits, 6.45um2 pixels, 8.8fps, QE : 60-72%
+
| Hamamatsu C4742-80, 1344x1024, 12 bits, 6.45um<sup>2</sup> pixels, 8.8fps, QE : 60-72%
 
|-
 
|-
 
|Nipkow Spinning Disk
 
|Nipkow Spinning Disk
Line 133: Line 133:
 
|-
 
|-
 
|Camera
 
|Camera
|Andor iXon 885 Em, 1004x1002,14 bits, 8um2,30fps, QE > 65%
+
|Andor iXon 885 Em, 1004x1002,14 bits, 8um<sup>2</sup>,30fps, QE > 65%
 
|-
 
|-
 
|Differential interference contrast (DIC)
 
|Differential interference contrast (DIC)
Line 155: Line 155:
 
|Piezo Z
 
|Piezo Z
 
|Yes
 
|Yes
 +
|-
 +
|Microablation System
 +
|No
 +
|}
 +
 +
==  Multi-Well Microscope ==
 +
 +
{|
 +
|Microscope
 +
| Zeiss AxioObserver Z1
 +
|-
 +
|Light Sources
 +
|Halogen Lamp, Xenon Arc Lamp
 +
|-
 +
|Camera
 +
|Andor Clara, 1392x1040, 14 & 16 bit, 6.45um<sup>2</sup>, 11fps, QE 40-60%
 +
|-
 +
|Differential interference contrast (DIC)
 +
|No
 +
|-
 +
|TIRF
 +
|No
 +
|-
 +
|Structured Light
 +
|No
 +
|-
 +
|Focus Stability
 +
|Yes (Definite Focus by Zeiss)
 +
|-
 +
|XYZ Motorized Stage
 +
|Yes
 +
|-
 +
|Nano Z Stage
 +
|No
 +
|-
 +
|Piezo Z
 +
|No
 
|-
 
|-
 
|Microablation System
 
|Microablation System
 
|No
 
|No
 
|}
 
|}

Revision as of 16:31, 17 January 2017

Raffi's Spinning Disk Confocal Microscope

Microscope Nikon TE2000
Light Sources Xeon Arc Lamp, Halogen Lamp, 4 Lasers (405nm, 488nm, 561nm, 636nm)
Wide Field Camera Photometrics CoolSNAP HQ, 1392x1040, 12 bits, 6.45um2 pixels, QE: 55-62%
Spinning Disk Camera QImaging Rolera-MGi, 512x512, 14 bits, 16um2, 30 fps, QE: up to 90%
Differential interference contrast (DIC) Yes
TIRF No
Structured Light No
Focus Stability Yes (Perfect Focus by Nikon)
XYZ Motorized Stage Yes
Nano Z Stage No
Piezo Z No
Microablation System Yes

Doxsey's Spinning Disk Confocal Microscope

Microscope Zeiss
Light Sources Mercury Arc Lamp, Halogen Lamp, 3 Lasers (491nm, 561nm, 647nm)
Wide-field Camera None
Spinning Disk Camera Hamamatsu C4742-80, 1344x1024, 12 bits, 6.45um2 pixels, 8.8fps, QE : 60-72%
Nipkow Spinning Disk Yokogawa CSU-10
Differential interference contrast (DIC) Unknown
TIRF No
Structured Light No
Focus Stability No
XYZ Motorized Stage Yes
Nano Z Stage No
Piezo Z Yes
Microablation System No

VESM

Microscope Olympus ix81
Light Sources Halogen Lamp, X-Cite LED 4 Color (395nm, 470nm,550nm, 640nm)
Camera 1 Andor Zyla CMOS 4.2, 2048x2048, 100fps, QE >70%
Camera 2 Andor Zyla CMOS 4.2, 2048x2048, 100fps, QE >70%
Differential interference contrast (DIC) No
TIRF No
Structured Light No
Focus Stability Soon (pgFocus by Karl Bellvé)
XYZ Motorized Stage No
Nano Z Stage No
Piezo Z Yes
Microablation System No

TESM

Microscope Olympus ix71
Light Sources Halogen Lamp, Lasers ( 405nm, 491nm, 561nm, 660nm )
Camera Andor iXon 885 Em, 1004x1002,14 bits, 8um2,30fps, QE > 65%
Differential interference contrast (DIC) No
TIRF Yes
Structured Light Yes
Focus Stability Yes (pgFocus by Karl Bellvé)
XYZ Motorized Stage No
Nano Z Stage No
Piezo Z Yes
Microablation System No

Multi-Well Microscope

Microscope Zeiss AxioObserver Z1
Light Sources Halogen Lamp, Xenon Arc Lamp
Camera Andor Clara, 1392x1040, 14 & 16 bit, 6.45um2, 11fps, QE 40-60%
Differential interference contrast (DIC) No
TIRF No
Structured Light No
Focus Stability Yes (Definite Focus by Zeiss)
XYZ Motorized Stage Yes
Nano Z Stage No
Piezo Z No
Microablation System No