Difference between revisions of "Microscopes"

From Wiki
Jump to navigation Jump to search
Line 3: Line 3:
  
 
{|
 
{|
 +
|Types of Imaging
 +
|Real Time Live Cell Imaging of fluorophores in modest to high quantity.
 +
|-
 
|Microscope
 
|Microscope
 
|Nikon TE2000   
 
|Nikon TE2000   
|-
 
|Types of Imaging
 
|Real Time Live Cell Imaging of fluorophores in modest to high quantity.
 
 
|-
 
|-
 
|Software
 
|Software
Line 52: Line 52:
  
 
{|
 
{|
 +
|Types of Imaging
 +
|Slower than Real Time Imaging of fluorophores in modest to high quantity.
 +
|-
 
|Microscope
 
|Microscope
 
|Zeiss
 
|Zeiss
|-
 
|Types of Imaging
 
|Slower than Real Time Imaging of fluorophores in modest to high quantity.
 
 
|-
 
|-
 
|Software
 
|Software
Line 101: Line 101:
  
 
{|
 
{|
|Microscope
 
| Olympus ix81
 
|-
 
 
|Types of Imaging
 
|Types of Imaging
 
|Faster than Real Time Live Cell Imaging of two fluorophores simultaneously in low to high quantity.
 
|Faster than Real Time Live Cell Imaging of two fluorophores simultaneously in low to high quantity.
 +
|-
 +
|Microscope
 +
|Olympus ix81
 
|-
 
|-
 
|Software
 
|Software
Line 150: Line 150:
  
 
{|
 
{|
 +
|Types of Imaging
 +
|Real Time Live Cell Imaging of fluorophores in low to high quantity near or in the plasma membrane.
 +
|-
 
|Microscope
 
|Microscope
 
| Olympus ix71
 
| Olympus ix71
|-
 
|Types of Imaging
 
|Real Time Live Cell Imaging of fluorophores in low to high quantity near or in the plasma membrane.
 
 
|-
 
|-
 
|Software
 
|Software
Line 193: Line 193:
  
 
{|
 
{|
|Microscope
 
| Zeiss Axio Observer Z1
 
|-
 
 
|Types of Imaging
 
|Types of Imaging
 
|Slow Live Cell Imaging of fluorophores in high quantity using 96 well plates.
 
|Slow Live Cell Imaging of fluorophores in high quantity using 96 well plates.
 +
|-
 +
|Microscope
 +
|Zeiss Axio Observer Z1
 
|-
 
|-
 
|Software
 
|Software

Revision as of 18:02, 17 January 2017

Raffi's Spinning Disk Confocal Microscope

Types of Imaging Real Time Live Cell Imaging of fluorophores in modest to high quantity.
Microscope Nikon TE2000
Software Metamorph
Light Sources Xeon Arc Lamp, Halogen Lamp, 4 Lasers (405nm, 488nm, 561nm, 636nm)
Wide Field Camera Photometrics CoolSNAP HQ, 1392x1040, 12 bits, 6.45um2 pixels, QE: 55-62%
Spinning Disk Camera QImaging Rolera-MGi, 512x512, 14 bits, 16um2 pixels, 30 fps, QE: up to 90%
Nipkow Spinning Disk Yokogawa CSU-10
Differential interference contrast (DIC) Yes
TIRF No
Structured Light No
Focus Stability Yes (Perfect Focus by Nikon)
XYZ Motorized Stage Yes
Nano Z Stage No
Piezo Z No
Microablation System Yes

Doxsey's Spinning Disk Confocal Microscope

Types of Imaging Slower than Real Time Imaging of fluorophores in modest to high quantity.
Microscope Zeiss
Software Metamorph
Light Sources Mercury Arc Lamp, Halogen Lamp, 3 Lasers (491nm, 561nm, 647nm)
Wide-field Camera None
Spinning Disk Camera Hamamatsu C4742-80, 1344x1024, 12 bits, 6.45um2 pixels, 8.8fps, QE : 60-72%
Nipkow Spinning Disk Yokogawa CSU-10
Differential interference contrast (DIC) Unknown
TIRF No
Structured Light No
Focus Stability No
XYZ Motorized Stage Yes
Nano Z Stage No
Piezo Z Yes
Microablation System No

VESM

Types of Imaging Faster than Real Time Live Cell Imaging of two fluorophores simultaneously in low to high quantity.
Microscope Olympus ix81
Software μManager
Light Sources Halogen Lamp, X-Cite LED 4 Color (395nm, 470nm, 550nm, 640nm)
Camera 1 Andor Zyla CMOS 4.2, 2048x2048, 12 & 16 bit modes, 6.45um2, 100fps, QE >70%
Camera 2 Andor Zyla CMOS 4.2, 2048x2048, 12 & 16 bit modes, 6.45um2, 100fps, QE >70%
Differential interference contrast (DIC) No
TIRF No
Structured Light No
Focus Stability Soon (pgFocus by Karl Bellvé)
XYZ Motorized Stage No
Nano Z Stage No
Piezo Z Yes
Microablation System No
Notes Housed in a Biosafety Level 2+ Room. Please see CDC Biosafety Level Criteria

TESM

Types of Imaging Real Time Live Cell Imaging of fluorophores in low to high quantity near or in the plasma membrane.
Microscope Olympus ix71
Software μManager
Light Sources Halogen Lamp, Lasers (405nm, 491nm, 561nm, 660nm )
Camera Andor iXon 885 Em, 1004x1002,14 bits, 8um2,30fps, QE > 65%
Differential interference contrast (DIC) No
TIRF Yes
Structured Light Yes
Focus Stability Yes (pgFocus by Karl Bellvé)
XYZ Motorized Stage No
Nano Z Stage No
Piezo Z Yes
Microablation System No

Multi-Well Microscope

Types of Imaging Slow Live Cell Imaging of fluorophores in high quantity using 96 well plates.
Microscope Zeiss Axio Observer Z1
Software μManager
Light Sources Halogen Lamp, Xenon Arc Lamp
Camera Andor Clara, 1392x1040, 14 & 16 bit, 6.45um2, 11fps, QE 40-60%
Differential interference contrast (DIC) No
TIRF No
Structured Light No
Focus Stability Yes (Definite Focus by Zeiss)
XYZ Motorized Stage Yes
Nano Z Stage No
Piezo Z No